Which warehouse chemicals reach the Tier II threshold?

Extremely hazardous substances such as sulfuric acid and anhydrous ammonia are reportable at 500 lb. Diesel, propane, gasoline, lead and other hazardous chemicals are reportable at 10,000 lb. Both are measured as the largest amount on site at any one time last year. Enter your amounts to check each one.

Reviewed November 2026 · 7 sources listed at the end

Example filled in: a 3PL building with 12 forklift batteries, a diesel generator tank and propane cylinders. Enter the largest amount on site on any one day last year.

ChemicalTier II thresholdMax on siteUnitSpecific gravity, if gallonsResult
Sulfuric acid (battery acid, all batteries)
EHS. Threshold planning quantity 1,000 lb
500 lb0
Lead acid batteries, total weight (EPA option for lead)
Not an EHS. Or add up lead itself
10,000 lb0
Diesel fuel (generator, fire pump, yard fueling)
Not an EHS
10,000 lb0
Propane (forklift cylinders and tanks)
Not an EHS
10,000 lb0
Anhydrous ammonia (refrigeration)
EHS. Threshold planning quantity 500 lb
500 lb0
Gasoline
Not an EHS. The 75,000 gal figure applies only to retail gas stations
10,000 lb0
Any other hazardous chemical with an SDS
Not an EHS
10,000 lb0

Checking

Extremely hazardous substances (EHS): report at 500 lb or the threshold planning quantity, whichever is lower: 40 CFR 370.10(a)(1).

All other hazardous chemicals: report at 10,000 lb: 40 CFR 370.10(a)(2)(i).

Gallons to pounds = gallons × specific gravity × 8.3, the method used by TCEQ's Tier II weight converter. Specific gravity is on the SDS.

Section 302 notice: any EHS at or over its threshold planning quantity: 40 CFR 355.10 and 355.12.

The two thresholds that matter in a warehouse

Federal Tier II reporting has two main thresholds. A chemical on EPA's list of extremely hazardous substances is reportable at 500 lb or its threshold planning quantity, whichever is lower. Every other hazardous chemical that needs a safety data sheet under OSHA is reportable at 10,000 lb. The test is the largest amount present at any one time during the calendar year, not the yearly total that passed through the building.

Thresholds from 40 CFR 370.10 and 40 CFR part 355, Appendix A, as published on eCFR, current to November 19, 2026.
ChemicalEHS?Threshold planning quantityTier II thresholdWhere it shows up
Sulfuric acid, CAS 7664-93-9Yes1,000 lb500 lbLead acid forklift and floor scrubber batteries
Anhydrous ammonia, CAS 7664-41-7Yes500 lb500 lbCold storage refrigeration systems
LeadNoNone10,000 lbLead acid batteries
Diesel fuelNoNone10,000 lbGenerator and fire pump tanks, yard fueling
PropaneNoNone10,000 lbForklift cylinders, bulk tanks
GasolineNoNone10,000 lbFleet fueling. Retail stations have a separate 75,000 gal threshold

Inventory you only store for customers still counts if it is a hazardous chemical present at the facility, unless an exemption in 40 CFR 370.13 applies, such as products in the same form and concentration as packaged for the general public. That exemption does not cover forklift batteries.

Gallons and pounds

Thresholds are in pounds. Tanks are measured in gallons. Multiply gallons by the specific gravity on the safety data sheet and by 8.3, the factor TCEQ's Tier II weight converter uses for the weight of a gallon of water. The example row uses a specific gravity of 0.85 for diesel only to show the math. Use the figure on your own SDS.

What the result means

If any row says Report, the facility owes a Tier II report for that chemical by March 1, filed in the state's system and sent to the state emergency response commission, the local emergency planning committee and the fire department. A state can set lower thresholds or add chemicals, so check your state's page as well.

If sulfuric acid or ammonia reaches its threshold planning quantity, the facility also owes a one-time emergency planning notice to the state commission and the local committee within 60 days under 40 CFR 355.20, and names a facility emergency coordinator.

Common questions

Is diesel in a generator tank reportable?

Yes, if the diesel on site reaches 10,000 lb at any one time. Include generator, fire pump and fueling tanks. The 100,000 gallon diesel figure in the rule applies only to retail gas stations with compliant underground tanks.

Do I add up propane cylinders?

Add the propane in every cylinder and tank on site to get the facility total, then compare it to 10,000 lb. EPA's mixture rule in 40 CFR 370.14 asks for the total quantity present throughout the facility.

Does inventory I store for a customer count?

It can. The rule covers hazardous chemicals present at the facility. Consumer packaged goods in the same form and concentration as sold to the public are exempt under 40 CFR 370.13.

We build the battery and chemical inventory, check every threshold and file in your state's system. $950 a site per year, $750 a site from the third site. State fees extra.