Warehouse Filings

How do you add up chemicals for Tier II thresholds?

For an extremely hazardous substance, add every pound on site: pure product plus the amount in every mixture and container, such as the acid in each forklift battery. For other hazardous chemicals you can count the mixture as a whole or add up the component. Skip components at 1% or less, or 0.1% for carcinogens.

Reviewed November 2026 ยท 6 sources listed at the end

Key facts
Extremely hazardous substancesAdd every pound on site, pure and in mixtures (40 CFR 370.14(a))
Other hazardous chemicalsCount the mixture as a whole, or add up the component
Components you can skip1% or less of a mixture; 0.1% or less for carcinogens (40 CFR 370.14(c))
Battery acid share EPA usedAbout 30% of battery weight, in the 2025 Allen Distribution order

Two rules, one for each kind of chemical

Source: 40 CFR 370.14(a), Table 1.
If the chemical isTo test the thresholdOn the report
An extremely hazardous substanceAdd the total present throughout the facility at any one time: pure product plus the amount in every mixture, even if you also count the mixtureReport the EHS itself, or report the mixture and name the EHS in it
Any other hazardous chemicalEither add the component across all mixtures and other forms, or count each mixture as a wholeReport the component, or report the mixture with its total quantity

The difference matters. For an extremely hazardous substance you have no choice: every pound on site is added, wherever it sits. For other hazardous chemicals you pick an approach, and EPA asks you to use the same approach for the section 311 submission and the Tier II report unless that is not possible (40 CFR 370.14(b)).

Working out the amount in a mixture

Multiply the concentration of the component, in weight percent, by the weight of the mixture in pounds (40 CFR 370.14(c)). You do not count a component at 1% or less of a mixture, or at 0.1% or less if it is a carcinogen. The section 302 rule uses the same method and the same 1% cutoff for threshold planning quantities (40 CFR 355.13 and 355.14).

Sample arithmetic for a fictional site. The 30% battery share is the figure EPA used in the Allen Distribution order; use the percentages on your own SDSs.
ItemCountWeight eachComponent shareComponent amount
Forklift batteries, sulfuric acid122,000 lb30%7,200 lb
Electrolyte stock, sulfuric acid2 carboys120 lb35%84 lb
Floor scrubber batteries, sulfuric acid2600 lb30%360 lb
Sulfuric acid on site7,644 lb

Batteries: the EHS and the rest

A lead acid battery is the classic case. EPA's memo on lead acid batteries treats each battery as a mixture of sulfuric acid, an extremely hazardous substance, and other hazardous chemicals such as lead, lead oxide and lead sulfate. The acid must be added across all batteries and any other sulfuric acid at the facility and compared with 500 lb. For the lead, EPA gives two options: compare the total weight of the batteries with 10,000 lb, or add up each component across the facility. EPA does not require aggregation of the non-EHS components.

At any one time

Thresholds are compared with the amount present at any one time, so the sum you need is for a single day: the day in the year when the total was highest. A chemical that moves through the building in lots of 2,000 lb never adds up to more than the most you held at once.

The whole facility

A facility, in 40 CFR 370.3, is all buildings, equipment and structures on a single site or on contiguous or adjacent sites owned or operated by the same person. Two buildings across a private yard under the same operator are usually one facility, and their totals are added. Separate sites in different places file separately. See multi-site companies.

Common questions

Do I add sulfuric acid from batteries and from stored acid together?

Yes. EPA's lead acid battery memo says the sulfuric acid in all batteries is added to any other sulfuric acid at the facility, in pure form or in mixtures.

Do I have to add up the lead in batteries?

No. EPA does not require aggregation of non-EHS components. You may compare total battery weight with 10,000 lb or add up each component.

Is the sum yearly?

No. It is the amount present at any one time, so use your highest single day.

We build the battery and chemical inventory, check every threshold and file in your state's system. $950 a site per year, $750 a site from the third site. State fees extra.

Get a quote