Warehouse Filings

What is the EPCRA section 311 SDS submission?

Section 311 is a one-time submission of safety data sheets, or a list of hazardous chemicals grouped by hazard, to the state commission, the LEPC and the fire department. It is due within three months after a chemical first reaches its threshold, and again within three months of significant new SDS information.

Reviewed November 2026 ยท 13 sources listed at the end

What section 311 asks for

Section 311 of EPCRA is the safety data sheet half of hazardous chemical reporting. Any facility that reaches a Tier II threshold for a chemical also owes a section 311 submission for that chemical. Under 40 CFR 370.30(a) there are two ways to do it:

  • Send the SDS for each hazardous chemical at or above its threshold, or
  • Send a list of those chemicals, grouped by the health and physical hazards in section 2 of their SDSs, using the chemical or common name shown on the SDS.

It goes to the state emergency response commission, the local emergency planning committee and the fire department with jurisdiction over the facility (40 CFR 370.32). Unlike Tier II it is not annual. It is a one-time submission with three triggers for an update.

Section 311 deadlines from 40 CFR 370.33, as published on eCFR, current to November 19, 2026.
TriggerWhat to sendDeadlineRule
A chemical first reaches its thresholdSDS or list entry for that chemicalWithin 3 months40 CFR 370.33(a)
Significant new information about a chemical already reportedRevised SDSWithin 3 months of discovering it40 CFR 370.33(b)
The LEPC asks for an SDS you have not sentThat SDS, at a threshold of zeroWithin 30 days of the request40 CFR 370.33(c) and 370.10(b)

Three months, or 30 days

EPA's general reporting guidance page answers the timing question with "within 30 days" of a chemical being present at or above the threshold. The regulation says three months: 40 CFR 370.33(a) gives a facility three months after it first becomes subject, and EPA's own section 311-312 overview page says new facilities have three months. We work to the regulation. If a state or LEPC sets a shorter local deadline, that local deadline applies on top.

Batteries and the 311 submission

For lead acid forklift batteries, EPA's memo expects most facilities to send the SDS for the battery itself, because battery SDSs are published for the battery rather than for each component, and then list the batteries on the Tier II form. 40 CFR 370.14(b) asks that a mixture be reported the same way under both sections where possible. If your Tier II lists sulfuric acid on its own, your section 311 submission should do the same.

The 2026 hazard category change

EPA's June 2026 rule moved EPCRA to OSHA's 2024 hazard classes and categories. EPA says a reclassified or added hazard category counts as significant new information, so facilities that used the list option send an updated list, and the new categories are required for section 311 lists by January 1, 2028. See what changes for 2027.

State extras

Some states fold section 311 into the Tier II filing. Pennsylvania requires an SDS for each chemical reported in PATTS. Vermont wants an SDS with the Tier II file for each newly reported material. Connecticut tells facilities to send site plans and SDSs to the LEPC and fire department with their reports. Check your state page before you rely on a one-time submission from years ago.

Penalty

A section 311 violation carries a federal civil penalty of up to $28,619 per violation for penalties assessed on or after January 8, 2025 (40 CFR 19.4, adjusting 42 U.S.C. 11045(c)(2)). The statute treats each day a violation continues as a separate violation.

Common questions

Is section 311 the same as Tier II?

No. Section 311 is the one-time SDS or list submission. Section 312, the Tier II inventory, is filed every year by March 1. Both apply to the same chemicals at the same thresholds.

Do I resend SDSs every year?

Federal rules do not require it. You send a revised SDS within three months of significant new information, and any SDS the LEPC asks for within 30 days. Some states ask for SDSs with each Tier II filing.

Which is easier, SDSs or the list?

The list is usually shorter for a warehouse, but it must be grouped by the hazard categories in section 2 of each SDS and kept current when those categories change.

We build the battery and chemical inventory, check every threshold and file in your state's system. $950 a site per year, $750 a site from the third site. State fees extra.

Get a quote