| Key facts | |
|---|---|
| Final rule | Published June 22, 2026, 91 FR 37022 |
| Effective | August 21, 2026 |
| Reports due March 1, 2027 | Use the current categories |
| New categories first apply | Reporting year 2027, in reports due March 1, 2028 |
| Section 311 lists | New categories from January 1, 2028 |
What EPA changed
Tier II reports classify each chemical by its health and physical hazards. Those categories come from OSHA's hazard communication standard, which OSHA revised in 2024. EPA's final rule, published June 22, 2026 at 91 FR 37022, conforms 40 CFR part 370 to OSHA's 2012 and 2024 amendments. The old EPCRA categories merged several OSHA hazard classes. The new ones use OSHA's hazard classes with their categories directly, plus hazards not otherwise classified. EPA's example: the old flammable category becomes 12 categories, and some hazards that used to be flammable now sit in other classes such as aerosols.
The new definitions are in 40 CFR 370.3, which now lists the health and physical hazard classes by name, including aerosols, chemicals under pressure, desensitized explosives and combustible dust.
The dates
| Date | What happens | Source |
|---|---|---|
| June 22, 2026 | Final rule published, 91 FR 37022 | Federal Register |
| August 21, 2026 | Rule effective | Federal Register |
| March 1, 2027 | Reports for reporting year 2026 due, under the current categories | EPA guidance |
| November 19, 2027 | OSHA's deadline for updated SDSs for mixtures | EPA guidance |
| January 1, 2028 | Compliance date for the new hazard categories, including section 311 lists | Federal Register |
| March 1, 2028 | First Tier II reports using the new categories, for reporting year 2027 | EPA guidance |
Renamed categories
For reporting year 2027 and later, three OSHA 2012 categories are reported under new names even if your SDS is older:
| 2012 OSHA hazard category | Report for 2027 or later as |
|---|---|
| Flammable Aerosols, Category 1 | Aerosols, Category 1 |
| Flammable Aerosols, Category 2 | Aerosols, Category 2 |
| Pyrophoric Gas | Flammable Gases, Pyrophoric Gas, Category 1A |
Going the other way, if you already have a 2024-format SDS for reporting years 2024 to 2026, EPA says 12 of its newer categories, such as Aerosols Categories 1 to 3, Chemicals Under Pressure and Desensitized Explosives, are reported as Hazard Not Otherwise Classified, and the pyrophoric gas category maps to Pyrophoric Gas.
Which SDS to use
OSHA set deadlines for manufacturers to update SDSs: May 20, 2024 to May 19, 2026 for substances, and May 20, 2024 to November 19, 2027 for mixtures. EPA modified its usual policy for this change. If you receive a revised SDS during 2026, you may use the SDS you already had for the report due March 1, 2027. The report due March 1, 2028 should use the revised SDS for both substances and mixtures, if available.
Downstream hazards and warehouses
OSHA's 2024 rule added a section 2(c) to SDSs for hazards from chemical reaction products in known or reasonably anticipated uses, such as two-part epoxies that are mixed before use. EPA has no binding policy on reporting these on Tier II and tells facilities to check with their state. Its recommended approach is to report them only if the hazards are reasonably anticipated to occur at the facility. EPA's own example is a warehouse: it would be inaccurate for a warehouse that houses epoxy chemicals to report the downstream hazards, but appropriate for an epoxy table manufacturer.
Section 311 lists
EPA says a reclassified or added hazard category counts as significant new information. Facilities that used the list option for section 311 send an updated list, using the new categories for every chemical, to the SERC, LEPC and fire department. The new categories are required for section 311 lists by January 1, 2028.
Common questions
Do thresholds change?
No. The rule changes hazard categories. The 500 lb and 10,000 lb thresholds in 40 CFR 370.10 stay the same.
Do warehouses report downstream hazards from SDS section 2(c)?
EPA recommends reporting them only where the hazard is reasonably anticipated at the facility, and uses a warehouse storing epoxies as an example of where it would be inaccurate. Your state may set its own rule.
Will Tier2 Submit and E-Plan change?
EPA says the revised Tier II form and instructions are published, and that a revised National Tier II Data Standard is planned for spring 2027 so software can be updated.
We build the battery and chemical inventory, check every threshold and file in your state's system. $950 a site per year, $750 a site from the third site. State fees extra.
Get a quote- Federal Register, 91 FR 37022, June 22, 2026, EPCRA hazardous chemical inventory reporting requirements: conformity with the 2024 OSHA HCS
- EPA, EPCRA hazardous chemical inventory reporting: revisions to hazard categories and reporting guidance
- 40 CFR 370.3, definitions (eCFR)