| Key facts | |
|---|---|
| Due | March 1, report and fee |
| Where you file | WHOPRS |
| State fee | $275 to $2,090 per facility by chemical count |
| Typical warehouse fee | $550 (battery acid and diesel, filed on time) |
| LEPC and fire department | Covered by state filing |
Where and how to file in Wisconsin
Wisconsin Emergency Management (WEM) / State Emergency Response Commission, EPCRA Program, Facility Reporting Section runs Tier II for the state. WHOPRS (Wisconsin Hazmat Online Planning and Reporting System, on the HazConnect platform); hard copy Wisconsin Tier II forms DMA 1004 and 1005 also accepted. The filing system is at wisconsin.hazconnect.com.
EPA's state page, last updated May 28, 2026, gives these instructions for Wisconsin:
Wisconsin accepts Tier Two data and other reporting requirements electronically using the WHOPRS website only. Wisconsin will accept hard copy submissions using Wisconsin state-specific forms only which can be found on the Wisconsin Forms and Resource webpage.
Fees in Wisconsin
Annual inventory form fee per facility by number of fee-subject chemicals, with a higher rate when the cumulative maximum daily amount is 100,000 lb or more (WEM 1.04(7), eff. 8-1-24): 1 chemical $275/$330; 2-10 $550/$655; 11-100 $825/$990; 101-200 $1,010/$1,210; 201-300 $1,195/$1,430; 301-400 $1,380/$1,650; 401-500 $1,560/$1,870; over 500 $1,745/$2,090. Operators with fewer than 10 FTE employees in Wisconsin are exempt; sand/gravel, resale motor fuel and road de-icing salts are excluded from the count. Separate one-time Emergency Planning Notification fee of $1,080 per facility for EHS at/above TPQ (WEM 1.03). The source reads: "For facilities submitting an inventory form listing 2 to 10 hazardous chemicals subject to inventory form fee calculations and a cumulative actual maximum daily amount of less than 100,000 pounds, $550." Fee source.
Late filing: 20% surcharge on the unpaid balance of a fee not paid by its due date (WEM 1.05).
Deadline
March 1 annually: Tier II report, site plan, inventory fee statement and fee must be received by WEM. Under federal rules the report is due on or before March 1 each year for the previous calendar year, so the report covering 2026 is due by March 1, 2027.
Copies to the LEPC and fire department
No, when filed in WHOPRS. The LEPC and local fire department access reports online, and WHOPRS submission meets the requirement.
State-specific requirements
Fields and attachments the state asks for
- Site plan required with the Tier II inventory form and inventory form fee statement. Source: docs.legis.wisconsin.gov
- Number of FTE employees in Wisconsin (all locations, all employee hours / 2,080) and the operator's EIN/Taxpayer ID, which must match its IRS W-9. Source: wem.wi.gov
- Reports must be certified in WHOPRS; an 'Initiated' report is incomplete. Choose the 'Annual' report type. Source: wem.wi.gov
State rules beyond federal Tier II
- One-time Emergency Planning Notification fee ($1,080 per facility) within 60 days of an EHS reaching TPQ, for operators with 10+ FTE in Wisconsin; 20% surcharge if late. Source: docs.legis.wisconsin.gov
- Section 311 SDS or chemical list due to WEM within 90 days of a new reportable chemical (no fee). Source: wem.wi.gov
- Wisconsin requires Tier II from facilities needing an OSHA SDS and from public or private agencies defined in Wis. Stat. 323.60(1)(h)-(i). Source: wem.wi.gov
Other things to know
- Fee exemption for operators with fewer than 10 FTE employees in the state. Source: wem.wi.gov
- Past-year reports and fees can be filed in WHOPRS or on a 'Past Years' form. Source: wem.wi.gov
- WHOPRS maintenance window Wednesdays 6:00-8:00 a.m. central; card payments get an email confirmation. Source: wem.wi.gov
- Hard-copy filings and checks go to WEM Fee Processing Service, Drawer 988, Milwaukee, WI 53293-0988; forms via [email protected] or 608-242-3224. Source: wem.wi.gov
Also checked on November 24, 2026
- Filing in WHOPRS satisfies the LEPC and fire department copies, since they read reports online. Source: wem.wi.gov
How to file in Wisconsin, step by step
The steps a first-time filer follows, from the state's own instructions as read on November 24, 2026:
- If an EHS (such as battery sulfuric acid) first reached its TPQ, file the Emergency Planning Notification in WHOPRS and pay the one-time $1,080 fee within 60 days. Source: wem.wi.gov
- Log in to WHOPRS and start an Annual report, entering the operator's Wisconsin FTE count and EIN, the site plan and each chemical (marking any fee exemptions). Source: wem.wi.gov
- Certify the report after submitting; a report still showing Initiated is incomplete. Source: wem.wi.gov
- Pay the inventory fee so WEM receives it with the report by March 1 (card payments get an email confirmation). Source: wem.wi.gov
What a typical warehouse pays in Wisconsin
Illustrative: one general warehouse (NAICS 493110), 40 employees, filing on time for calendar year 2026, reporting two chemicals: sulfuric acid in lead acid forklift batteries (an extremely hazardous substance, 7,260 lb on site) and diesel in a generator tank (11,900 lb). Applying the state's published fee rule, that warehouse pays $550 to the state for the year.
How it adds up: 2 fee-subject chemicals (diesel 11,900 lb + sulfuric acid 7,260 lb = 19,160 lb cumulative, under 100,000 lb) = WEM 1.04(7)(b) rate $550. Route assumed: WHOPRS (Wisconsin Hazmat Online Planning and Reporting System on HazConnect), fee paid by card in WHOPRS or by check with the Inventory Fee Invoice; E-Plan not used, so no E-Plan charge. 40 employees means 10 or more FTE in Wisconsin, so no employee exemption; the generator diesel is not motor fuel held for resale, so it counts. Excludes the separate one-time $1,080 Emergency Planning Notification fee that applies within 60 days of sulfuric acid first reaching its TPQ (assumed already paid in an earlier year); paid by March 1, so no 20 percent surcharge.
Local fees, if any, are not included. Compare every state on what Tier II costs per facility. Fee rule: docs.legis.wisconsin.gov
Does Wisconsin use the federal thresholds?
Wisconsin's annual Tier II uses the federal thresholds: 10,000 lb for hazardous chemicals and 500 lb or the TPQ (whichever is less) for EHS. Source: wem.wi.gov
Federal thresholds under 40 CFR 370.10: 500 lb or the threshold planning quantity, whichever is lower, for extremely hazardous substances such as the sulfuric acid in forklift batteries, and 10,000 lb for other hazardous chemicals such as diesel and propane.
Penalties in Wisconsin
A fee not paid by its due date (March 1 for the inventory fee) carries a 20 percent surcharge on the unpaid balance (WEM 1.05). Source: docs.legis.wisconsin.gov
Federal penalties apply everywhere: up to $71,545 per section 312 violation, each day counted separately. See Tier II penalties for warehouse cases.
Who to contact in Wisconsin
Wisconsin Emergency Management (WEM), EPCRA Program, Facility Reporting, PO Box 7865, Madison, WI 53707-7865: phone 608-242-3224 or 608-242-3225. Source: wem.wi.gov
What warehouses in Wisconsin usually report
Most warehouse Tier II reports start with the sulfuric acid in lead acid forklift batteries. Sulfuric acid is an extremely hazardous substance, so the acid in every battery on site, spares included, is added up and compared to 500 lb. EPA says the consumer product exemption does not apply to forklift batteries. After that come diesel in generator and fire pump tanks, propane cylinders, and anhydrous ammonia in cold storage. The battery calculator and the threshold checker run the numbers.
Other states: West Virginia · Wyoming · all states
Common questions
Does Wisconsin charge a Tier II fee?
The state fee is $275 to $2,090 per facility by chemical count. Source: docs.legis.wisconsin.gov.
Where do I file Tier II in Wisconsin?
WHOPRS (Wisconsin Hazmat Online Planning and Reporting System, on the HazConnect platform); hard copy Wisconsin Tier II forms DMA 1004 and 1005 also accepted.
Do I send copies to the LEPC and fire department in Wisconsin?
No, when filed in WHOPRS. The LEPC and local fire department access reports online, and WHOPRS submission meets the requirement.
When is the Wisconsin Tier II report due?
March 1 annually: Tier II report, site plan, inventory fee statement and fee must be received by WEM. Under federal rules the report is due on or before March 1 each year for the previous calendar year, so the report covering 2026 is due by March 1, 2027.
Is there a late fee for Tier II in Wisconsin?
20% surcharge on the unpaid balance of a fee not paid by its due date (WEM 1.05).
How much does a typical warehouse pay for Tier II in Wisconsin?
$550 in state fees for one warehouse reporting battery acid and generator diesel, filed on time: 2 fee-subject chemicals (diesel 11,900 lb + sulfuric acid 7,260 lb = 19,160 lb cumulative, under 100,000 lb) = WEM 1.04(7)(b) rate $550. Local fees are not included.
Does Wisconsin have lower Tier II thresholds than the federal rule?
Wisconsin's annual Tier II uses the federal thresholds: 10,000 lb for hazardous chemicals and 500 lb or the TPQ (whichever is less) for EHS.
Who do I contact about Tier II in Wisconsin?
Wisconsin Emergency Management (WEM), EPCRA Program, Facility Reporting, PO Box 7865, Madison, WI 53707-7865: phone 608-242-3224 or 608-242-3225.
We build the battery and chemical inventory, check every threshold and file in your state's system. $950 a site per year, $750 a site from the third site. State fees extra.
Get a quote- Wisconsin Emergency Management (WEM) / State Emergency Response Commission, EPCRA Program, Facility Reporting Section, Tier II page
- Wisconsin fee source
- Wisconsin copies to LEPC and fire department
- Wisconsin: Reports must be certified in WHOPRS; an 'Initiated' report is incomple
- EPA, State Tier II Reporting Requirements and Procedures (updated May 28, 2026)
- 40 CFR 370.45, when inventory information is due (eCFR)
- 40 CFR 370.44, who receives the report (eCFR)
- EPA, Forklift batteries