| Key facts | |
|---|---|
| Records checked | 5 GB motive-power battery models |
| Evidence retrieved | November 24, 2026 |
| SDS revision | March 16, 2015; generic industrial battery |
| Critical input | Sulfuric acid percentage of whole battery, not electrolyte |
Five published model records, with both denominators
The rows below transcribe GB Industrial Battery's hazardous-material specification table. The two percentage columns are our calculations, not manufacturer certifications. All weights are pounds; voltage is volts. These are five selected records from one manufacturer's published table, not a representative sample of forklift batteries.
| GB model | V | Whole battery lb | Electrolyte lb | Sulfuric acid lb | Acid / battery | Acid / electrolyte |
|---|---|---|---|---|---|---|
| 12-85-13 | 24 | 1,035 | 206.52 | 78.12 | 7.55% | 37.83% |
| 18-85-13 | 36 | 1,525 | 309.78 | 117.18 | 7.68% | 37.83% |
| 18-85-17 | 36 | 2,065 | 412.92 | 156.24 | 7.57% | 37.84% |
| 18-85-21 | 36 | 2,530 | 516.24 | 195.30 | 7.72% | 37.83% |
| 24-85-13 | 48 | 2,015 | 413.04 | 156.24 | 7.75% | 37.83% |
Source-age limit: the model table displays a February 3, 2007 update footer. We retrieved it on November 24, 2026. Retrieval confirms what is published, not that these values describe a battery manufactured today. Match the manufacturer, model, tray and current documentation before using a row for a facility inventory.
Why the denominator changes the answer
For any battery, acid mass divided by whole-battery mass is a different fraction from acid mass divided by electrolyte-solution mass. The liquid solution includes water. The whole battery also includes the plates, case and other components. A useful worksheet therefore gives every percentage an explicit denominator.
- Known acid pounds per unit: multiply that mass by the count of matching units.
- Acid percentage of the whole battery: multiply battery pounds by that percentage divided by 100.
- Acid percentage of the electrolyte: multiply electrolyte pounds by that percentage divided by 100.
- Only electrolyte gallons available: obtain the applicable solution density before converting to pounds.
A purely illustrative 2,000 lb battery with 400 lb of electrolyte at 38% acid contains 152 lb of acid. Its acid fraction of total battery weight is 7.6%. Multiplying 2,000 by 38% would instead produce 760 lb, five times the correct result for that hypothetical set of inputs. These example values do not describe an additional verified model.
What the manufacturer's SDS does and does not verify
The GB wet lead-acid battery SDS, revision March 16, 2015, lists electrolyte (H2SO4/H2O) at 21% by weight in Section 3, PDF page 4. It says the ingredients represent a typical industrial battery. That 21% describes the acid-and-water mixture; treating all of it as sulfuric acid drops the water from the calculation without evidence.
The file also includes an older two-page MSDS ahead of the ten-page SDS. Its different composition presentation must not be silently combined with the later sheet. The generic SDS does not establish that a particular serial number matches one of these table rows, and it does not supply an exact model-specific pure-acid fraction. We use the model table's separately published acid pounds for this comparison, retaining the age and applicability limits.
Unresolved inputs for an actual facility remain the unit's exact configuration, service weight, electrolyte fill and charge condition, current manufacturer documentation, and the largest concurrent on-site inventory. Ask the manufacturer to resolve discrepancies between a nameplate, a model table and an SDS. Do not average conflicting figures to manufacture a precise answer.
How to carry verified inputs into the calculator
The forklift battery calculator expects sulfuric acid as a percentage of whole-battery weight. Use the column headed Acid / battery only after confirming the row applies to your units. Do not put the Acid / electrolyte column, or the SDS's 21% electrolyte fraction, in that field.
For mixed models, calculate acid mass for each matching group and add the group totals. An average battery weight combined with an unrelated average percentage can give a wrong total. Keep unrounded acid pounds in the working file; the displayed percentages here are rounded to two decimals. A rounded percentage entered into the calculator may not reproduce the published acid weight exactly.
The calculator's existing 30% example comes from a different enforcement record. It is not a manufacturer default for these five GB records. A case-specific percentage and a generic SDS are evidence with different scopes; neither replaces the documentation for the batteries at your facility.
What EPA requires you to compare
EPA's battery reporting FAQ directs facilities to aggregate sulfuric acid across batteries. It gives the EHS reporting threshold as 500 lb or the threshold planning quantity, whichever is lower, and identifies sulfuric acid's TPQ as 1,000 lb. That makes the federal Tier II threshold for sulfuric acid 500 lb. This guide is a mass-input comparison, not a determination of your full reporting obligations.
EPA's forklift-battery FAQ says the consumer-product exemption does not apply to batteries normally used in electric forklifts. Check the state reporting guide for the facility's location, and return to the Tier II hub for the reporting workflow. Other chemicals and state requirements need their own evaluation.
Download the records and reproduce the check
Download the five-model CSV or JSON with source evidence. Each record retains the source URL, the source row, the two denominator formulas, and the verification limits. The JSON records retrieval timestamps and SHA-256 hashes for the four source snapshots retained with our research.
Our method was to retrieve the manufacturer's table and SDS plus two EPA FAQs, visually inspect the SDS composition page, extract five model rows, and compute acid pounds divided by each stated denominator. No laboratory testing, manufacturer confirmation or inspection of a customer's battery was performed. A hash identifies the downloaded evidence; it does not validate the manufacturer's underlying measurement. Corrections belong in the source record before the public table is regenerated.
Common questions
Can I use 21% from the GB SDS as pure sulfuric acid?
No. Section 3 identifies that entry as electrolyte containing sulfuric acid and water. Obtain the acid mass or the acid concentration within that mixture before calculating pure-acid pounds.
Do these records certify the batteries at my warehouse?
No. These are published historical model specifications. Confirm the exact manufacturer, configuration and current documentation for each unit before using them in a facility inventory.
Which percentage goes into the forklift battery calculator?
The calculator takes acid as a percentage of whole-battery weight. Use acid pounds divided by whole-battery pounds, multiplied by 100; an electrolyte-based percentage needs a different mass input.
Is this an independent laboratory study?
No. Warehouse Filings transcribed manufacturer records and calculated ratios. We did not test batteries or independently measure their chemical contents.
We build the battery and chemical inventory, check every threshold and file in your state's system. $950 a site per year, $750 a site from the third site. State fees extra.
Get a quote