Warehouse Filings

Who files the Tier II report when a 3PL runs the warehouse?

Federal rules put the duty on the owner or operator of the facility, and one report covers the whole site. In a 3PL building that can be the 3PL, its client or the landlord, so settle it in writing. Battery acid and stored chemicals count whoever owns them, at 500 lb or 10,000 lb. Warehouse Filings (this site) files for 3PLs and their clients once the filer is agreed: $950 a site, $750 from the third.

Updated November 24, 2026 ยท 10 sources listed at the end

Key facts
Who filesThe owner or operator of the facility (40 CFR 370.2)
FacilityAll buildings on one site, or adjacent sites, owned or operated by the same person (40 CFR 370.3)
ReportsOne report covers the whole site, including clients' chemicals
Thresholds500 lb for battery acid and other extremely hazardous substances; 10,000 lb for others
DueMarch 1, for the previous calendar year

What the rule says

Federal Tier II rules are written to the owner or operator of a facility. 40 CFR 370.2 says that every "you" in part 370 means the owner or operator. The duty starts when OSHA's hazard communication standard requires a safety data sheet for a hazardous chemical at the facility and that chemical reaches its threshold at any one time during the year.

The rule does not say the building owner files, or the company whose goods are on the racks. It says the owner or operator. In a 3PL setting those can be three different companies, so the answer depends on the contract and on who runs the site day to day.

What counts as the facility

A facility, under 40 CFR 370.3, is every building, piece of equipment and structure on a single site, or on contiguous or adjacent sites, owned or operated by the same person. The definition also reaches any person that controls, is controlled by, or is under common control with that person. Two buildings across a shared yard, run by the same 3PL, are one facility for Tier II. A building the 3PL runs across town is a separate facility with its own report.

Common 3PL arrangements. The rule places the duty on the owner or operator; the contract decides who does the work.
SetupOwnerOperatorWhat to settle in writing
3PL leases a building and runs it for several clientsLandlord3PLThat the 3PL counts all chemicals on site, its own and its clients', and certifies one report
3PL runs a dedicated building leased by its clientLandlord3PL, under contract to the clientWhether the client or the 3PL files, who certifies, and who supplies battery and SDS data
Client owns the building and the 3PL staffs itClient3PL or client, by contractWho is named as owner or operator on the report and who signs the certification
Landlord keeps diesel generator or fire pump tanksLandlordTenant runs the warehouseThat the landlord's tanks are on the report, because they are part of the facility

Chemicals you store for customers

A hazardous chemical present at the facility counts toward the threshold, whoever owns it. 40 CFR 370.13 exempts a few categories: food, drugs and cosmetics regulated by FDA, solids in manufactured items where exposure does not occur in normal use, and substances present in the same form and concentration as a product packaged for the general public. Retail-packaged goods on a pallet often fall in that last group. Bulk drums, totes and industrial products usually do not.

The equipment that runs the building is where most 3PL reports start. EPA says the consumer product exemption does not apply to the batteries in electric forklifts, and that the chemicals in them count toward the section 311 and 312 thresholds. EPA also says large commercial lithium-ion batteries that are not available to the general public do not get the consumer product exemption.

Whose name goes on the report

The Tier II form asks for the name, mailing address, phone number and email address of the owner or operator (40 CFR 370.42(m)). The parent company's name and details are optional (370.42(n)). The form also names a facility emergency coordinator where one is required, a person to contact about the report, and a local emergency contact with a phone number answered 24 hours a day.

The certification must be signed by the owner or operator, or by the officially designated representative of the owner or operator (370.42(a)). That is the line a 3PL contract should address: which company's officer, or which designated representative, signs.

Some states add their own name rules. Wisconsin says the owner or operator name on the report must match the EIN on its IRS form W-9. Wyoming says a Tier II reporter's company name must be assigned to every facility it owns and files on. Iowa notes that when a facility is sold during the year, both parties may have to report the same facility for that year.

The packaging filing a 3PL can owe too

A 3PL that packs and ships orders can also owe packaging EPR on the boxes and mailers it adds. In Oregon the statute says "the producer of packaging used to ship the item to a consumer is the person that packages and ships the item to the consumer" (ORS 459A.866), and Colorado, Washington, Minnesota, Maryland and Maine use the same packer rule. Our sister site EPR HQ explains how brands and 3PLs split it: packaging EPR when a 3PL packs your orders.

How we handle 3PL sites

We build the inventory for the whole facility, including client inventory and landlord equipment, and send a draft to whoever certifies. You decide who files; we prepare the report either way. $950 a site per year, $750 a site from the third site, state fees extra.

For a 3PL with buildings in several states, each building is its own report in its own state's system, with its own fee rule. The multi-site guide works through a five-state network with every state fee, and the Tier II data checklist includes a line for client chemicals with their SDSs.

Common questions

Can the 3PL sign the report for its client?

The certification must come from the owner or operator, or the officially designated representative of the owner or operator, under 40 CFR 370.42(a). If the client is the filer, it can designate a representative to certify.

Does inventory that only passes through count?

The test is the largest amount present at any one time during the calendar year. Fast-moving inventory still counts on the days it is in the building, unless an exemption in 40 CFR 370.13 applies.

Do we file one report per client?

No. Tier II is filed per facility. Every reportable chemical at the site goes on that facility's report, whatever client it belongs to.

We build the battery and chemical inventory, check every threshold and file in your state's system. $950 a site per year, $750 a site from the third site. State fees extra.

Get a quote